beautypg.com

Model 505.90 hpu specifications, Model 505.90 hpu specifications 34 – MTS Series 505 SilentFlo Hydraulic Power Unit Model 505-180 User Manual

Page 34

background image

Model 505.60 - 505.180 SilentFlo™ HPU

34

Model 505.90 HPU Specifications

Introduction

Model 505.90 HPU Specifications

Parameter

Specification

Pump/Motor

Number of pump/motors

Maximum continuous
pressure

Maximum flow capacity

Motor rating

*

Current draw

*

For one motor

† For all motors

Wye-Delta starter configuration

3

21 MPa (3000 psi)

300 L/m (80 gpm) at 50 Hz
340 L/m (90 gpm) at 60 Hz

45 kW (60 hp) at 50/60 Hz

233 A continuous at 460 V AC 60 Hz
281 A continuous at 380 V AC 50 Hz

Reservoir capacity

950 L (250 gal) maximum
605 L (160 gal) minimum

Water flow rating
(input temperature)

10°C (50°F)

15.5°C (60°F)

21.1°C (70°F)

26.7°C (80°F)

32.2°C (90°F)

Heat load (maximum)

56.0 L/m (14.8 gpm)

64.3 L/m (17 gpm)

83.3 L/m (22 gpm)

128.7 L/m (34 gpm)

268.7 L/m (71 gpm)

134.4 kW (459,000 Btu/hr)

Dimensions

Length

Height

Width

2870 mm (113 in)

2006 mm (79 in)

990 mm (39 in)

Weight

Empty

With hydraulic fluid

2138 kg (4714 lb)

2711 kg (5977 lb) minimum fluid level
3051 kg (6726 lb) maximum fluid level

Noise

rating at 1 m

‡ Sound pressure level [dB(A)] is expressed as a free field value.

Readings may vary with the acoustic environment.

68 dB(A) fully compensated