Specifications, Model 505.60–505.180 hpu general specifications, Specifications 32 – MTS Series 505 SilentFlo Hydraulic Power Unit Model 505-180 User Manual
Page 32: Model 505.60–505.180 hpu general specifications 32

Model 505.60 - 505.180 SilentFlo™ HPU
32
Specifications
Introduction
Specifications
Model 505.60–505.180 HPU General Specifications
Parameter
Specification
Environmental
Operating temperature
Humidity
For use in a controlled environment.
5–40°C (40–104°F)
0–85% noncondensing
Hydraulic fluid
Typical operating
temperature range
Filtration (microns)
Output Pressure
Non-adjustable relief valve
setting
Exxon Mobil DTE 25 or Shell Tellus 46 AW
43–49°C (110–120°F)
3 microns nominal
21 MPa (3000 psi)
22.4 MPa (3250 psi)
Heat exchanger
Water pressure
Maximum pressure
Water hose (.60/.90)
Water hose (.120/.150/.180)
Typical operating range
Max tempinterlock pre-set
Water-cooled
0.2–0.3 MPa (35–45 psi differential)
0.8 MPa (120 psi)
38 mm (1.5 in) NPT
51 mm (2 in) NPT
43-49°C (110-120°F)
55°C (131°F)
Hydraulic connections
Pressure
Return
Drain
2 inch SAE
2 inch SAE
-16 JIC
Electrical Power
Line voltage
Control voltage
380–575 V AC
24 V DC