Model 505.60 hpu setup, Model 505.60 hpu setup 70 – MTS Series 505 SilentFlo Hydraulic Power Unit Model 505-180 User Manual

Page 70

background image

Model 505.60 - 505.180 SilentFlo™ HPU

70

Model 505.60 HPU Setup

Operation

Model 505.60 HPU Setup

Pressure Filter
display

Indicates yellow when the filter needs replacement. The signal can be
monitored from the system controller.

Refer to the appropriate filter replacement procedure if necessary.

After replacing the filter, press the Reset button to clear the indication. The
indicator returns to Pressure Filter Normal (green).

Pump Motor Overload
Fault Status
display

Monitors each enabled pump motor and indicates red when a thermal overload
has been detected.

Pump Motor Run Status
display

Indicates the current run status of each pump. The possible conditions are:

Enabled

Offline

On-Low

On-High

Standby (After the first pump starts, this term displays on all
remaining enabled pumps until they start.)

HPU Status Screen (Continued)

Control

Descriptions