Model 505.150 hpu specifications, Model 505.150 hpu specifications 36 – MTS Series 505 SilentFlo Hydraulic Power Unit Model 505-180 User Manual
Page 36
Model 505.60 - 505.180 SilentFlo™ HPU
36
Model 505.150 HPU Specifications
Introduction
Model 505.150 HPU Specifications
Parameter
Specification
Pump/Motor
Number of pump/motors
Maximum continuous
pressure
Maximum flow capacity
Motor rating
*
Current draw
†
*
For one motor
† For all motors
Wye-Delta starter configuration
5
21 MPa (3000 psi)
500 L/m (133 gpm) at 50 Hz
567 L/m (150 gpm) at 60 Hz
45 kW (60 hp) at 50/60 Hz
387 A continuous at 460 V AC 60 Hz
476 A continuous at 380 V AC 50 Hz
Reservoir capacity
1893 L (500 gal) maximum
1211 L (320 gal) minimum
Water flow rating
(input temperature)
10°C (50°F)
15.5°C (60°F)
21.1°C (70°F)
26.7°C (80°F)
32.2°C (90°F)
Heat load (maximum)
87.8 L/m (23.2 gpm)
94.6 L/m (25 gpm)
121.1 L/m (32 gpm)
159.0 L/m (42.0 gpm)
265.0 L/m (70 gpm)
224 kW (765,000 Btu/hr)
Dimensions
Length
Height
Width
4270 mm (168 in)
2006 mm (79 in)
990 mm (39 in)
Weight
Empty
With hydraulic fluid
3313 kg (7305 lb)
4372 kg (9638 lb) minimum fluid level
4979 kg (10977 lb) maximum fluid level
Noise
‡
rating at 1 m
‡ Sound pressure level [dB(A)] is expressed as a free field value.
Readings may vary with the acoustic environment.
71 dB(A) fully compensated