Adjusting the model 505.60 hydraulic pressure, Adjusting the model 505.60 hydraulic pressure 81 – MTS Series 505 SilentFlo Hydraulic Power Unit Model 505-180 User Manual
Page 81

Adjusting the Model 505.60 Hydraulic Pressure
Model 505.60 - 505.180 SilentFlo™ HPU
Operation
81
Adjusting the Model 505.60 Hydraulic Pressure
The output pressure can be adjusted from a low pressure value of 1 MPa (145
psi) to the maximum setting of 21 MPa (3000 psi). If you have a special testing
requirement, you can reduce the HPU output pressure.
Control Locations (505.69/90 shown)
Perform the following procedure to adjust the output pressure. Perform this
procedure on one pump at a time.
The pump and motor are designed to operate below a specified pressure.
Setting the hydraulic pressure above 21 MPa (3000 psi) can damage the
pump and its motor
Do not adjust the output pressure higher than 21 MPa (3000 psi).
Pump
Assemblies
Output
Pressure
Controls
User
Interface
Panel
CAUTION