MTS Series 505 SilentFlo Hydraulic Power Unit Model 505-180 User Manual

Page 51

background image

Model 505.60—505.180 HPU Electrical, Hydraulic, and

Model 505.60 - 505.180 SilentFlo™ HPU

Installation

51

D.

A regulating valve must be adjusted according to your water
temperature. For a description of how to set the water regulating valve
see, the “Changing the Water Flow” procedure.

The water supply must also be capable of maintaining water flow at a rate
listed in the following table.

5. Add hydraulic fluid to the reservoir.

The unit is shipped with a plug in the filler cap. Remove the red filler cap
plug and install the screen in the fill port on the top of the reservoir. The
screen is shipped in the electrical enclosure.

Pump hydraulic fluid (filtered to 10 microns) into the reservoir. Stop when
the fluid level reaches the maximum fluid level as indicated by the oil level
dial gage

.

6. If provided, check the precharge pressure of the optional surge suppressor.

Refer to the appropriate procedure for complete instructions.

Water
Temperature

Model Number

505.60

505.90

505.120

505.150

505.180

10.0°C (50°F)

34.1 L/m
(9.0 gpm)

56.0 L/m
(14.8 gpm)

68.1 L/m
(18.0 gpm)

87.8 L/m
(23.2 gpm)

112.0 L/m
(29.6 gpm)

15.5°C (60°F)

41.6 L/m
(11 gpm)

64.3 L/m
(17 gpm)

71.9 L/m
(19 gpm)

94.6 L/m
(25 gpm)

128.7 L/m
(34 gpm)

21.1°C (70°F)

56.8 L/m
(15 gpm

83.3 L/m
(22 gpm)

90.8 L/m
(24 gpm)

121.1 L/m
(32 gpm)

166.5 L/m
(44 gpm)

26.7°C (80°F)

83.3 L/m
(22 gpm)

128.7 L/m
(34 gpm)

113.6 L/m
(30 gpm)

159.0 L/m
(42 gpm)

257.4 L/m
(68 gpm)

32.2°C (90°F)

177.9 L/m
(47 gpm)

268.7 L/m
(71 gpm)

174.1 L/m
(46 gpm)

265.0 L/m
(70 gpm)

537.5 L/m
(142 gpm)