C13887 | suppress signalling diag. mess. upon, C13899 | station name, C13900 | firmware product type – Lenze E84DxxxxxxxxxR User Manual
Page 76: C13864, C13899, Communication manual 8400 protec profinet

Communication manual 8400 protec PROFINET
Parameter reference
Parameters relevant for communication
76
L
EDS84DPNET EN 4.0 - 11/2010
C13887
C13899
C13900
Parameter | Name:
C13887 | Suppress signalling diag. mess. upon
Data type: BITFIELD_8
Index: 10688
d
= 29C0
h
This code serves to inhibit the transmission of alarm messages to the IO controller. By this, errors of a specific type
can be systematically suppressed. All errors are entered in the logbook furthermore.
• A change will only become effective immediately if no error number with the error type selected here is pending
in C00165.
Value is bit-coded:
Information
Bit 0 Error
Bit 1 Trouble
Bit 2 Quick stop by trouble
Bit 3 Warning locked
Bit 4 Warning
Bit 5 Reserved
Bit 6 Reserved
Bit 7 Reserved
;
Read access ; Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13899 | Station name
Data type: VISIBLE_STRING
Index: 10676
d
= 29B4
h
The name with a max. length of 240 characters is distributed to the subindices. The name can be entered starting
with subindex 1. The following, unused subindices are not relevant.
• The station name must be assigned in accordance with the PROFINET specification. In the standard setting a
deleted name is displayed. The name is also deleted if the "Reset to factory defaults" command is executed by an
IO supervisor or an IO controller.
• A change of the station name will only become effective by switching the mains of the controller.
Setting the station name ( 25)
Subcodes
Lenze setting
Information
C13899/1
1st ... 30th character
C13899/2
31st ... 60th character
C13899/3
61st ... 90th character
C13899/4
91st ... 120th character
C13899/5
121st ... 150th character
C13899/6
151st ... 180th character
C13899/7
181st ... 210th character
C13899/8
211th ... 240th character
;
Read access ; Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13900 | Firmware product type
Data type: VISIBLE_STRING
Index: 10675
d
= 29B3
h
The code contains a string with a length of 8 bytes. The identification code "E84DFYER" is displayed.
;
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT