C13877 | bus error(1), C13878 | bus error(2), Communication manual 8400 protec profinet – Lenze E84DxxxxxxxxxR User Manual
Page 74
Communication manual 8400 protec PROFINET
Parameter reference
Parameters relevant for communication
74
L
EDS84DPNET EN 4.0 - 11/2010
C13877
C13878
Parameter | Name:
C13877 | Bus error(1)
Data type: UNSIGNED_16
Index: 10698
d
= 29CA
h
The code contains the error currently detected on the fieldbus.
• The error values can occur in combination with the error values from code
.
Selection list
(read only)
Information
0 No fail
1 Internal error
2 Unit ID unknown
3 Max. units exceeded
4 Invalid size
5 Unit type unknown
6 Runtime plug
7 Invalid argument
8 Service pending
9 Stack not ready
10 Command unknown
11 Invalid address descriptor
12 Watchdog expired
13 Protocol not supported
;
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C13878 | Bus error(2)
Data type: BITFIELD_16
Index: 10697
d
= 29C9
h
The code contains the error currently detected on the fieldbus.
• The error values can occur in combination with the error values from code
.
Value is bit-coded:
Information
Bit 0 Reserved
... ...
Bit 6 Reserved
Bit 7 IP address error
Bit 8 Station name error
Bit 9 DataExch left
Bit 10 Stack boot error
Bit 11 Stack online error
Bit 12 Stack state error
Bit 13 Stack revision error
Bit 14 Stack init error
Bit 15 Stack CPU boot error
;
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT