Lenze E84DxxxxxxxxxR User Manual
Page 12

Communication manual 8400 protec PROFINET
General information
12
L
EDS84DPNET EN 4.0 - 11/2010
Properties of the PROFINET with Inverter Drives 8400 protec
Support of the I&M0 ... 4 functionality for the identification of the Inverter Drive 8400
protec
Transmission of safe information via the PROFIsafe protocol when using a version with
an integrated safety system
Up to 16 process data words can be exchanged for each direction.
Automatic detection of the baud rate 100 Mbps
A line topology is enabled by the integrated 2-port switch.
Support of the LLDP (Link Layer Discovery Protocol) for the topology recognition
Support of the SNMP (Simple Network Management Protocol) for diagnostics
Support of the MRP (Media Redundancy Protocol)
– The Inverter Drive 8400 protec can be integrated into a ring topology as a client node.
Device replacement without exchangeable disk storage
– Since the "station alias" is supported, a station name is automatically assigned to the
new PROFINET node.
– For storing the parameters of the controller, a memory module is still required.
Access to all Lenze parameters
Safety engineering manual "Inverter Drives 8400 protec"
Here you can find detailed information on devices with an integrated safety
system.