8 diagnostics, 1 display, 8diagnostics – Lenze S94P01B2 User Manual
Page 67: Diagnostics

S94P01B2
65
Diagnostics
8
Diagnostics
8.1
Display
The PositionServo 940 drives are equipped with a diagnostic LED display and 3 push
buttons to select displayed information and to edit a limited set of parameter values.
Parameters can be scrolled by using the “UP” and “DOWN” (
) buttons. To view a
value, press “Enter”( ). To return back to scroll mode press “Enter” again.
After pressing the ”Enter” button on editable parameters, the yellow LED “C” (see figure
in the next section) will blink indicating that parameter value can be changed. Use “UP”
and “DOWN” buttons to change the value. Press “Enter” to store new setting and return
back to scroll mode.
Display
Description
StAt
current drive status - to view:
run
- drive running
diS
- drive disabled
F_
XX - drive fault. Where XX is the fault code (section 8.3.1)
H
x.xx
Hardware revision (e.g. H2.00)
F
x.xx
Firmware revision (e.g. F2.06)
bAUd
RS232/RS485(normal mode) baud rate - to set
selects from 2400 to 115200 baudrates
Adr
Drive’s address - to set
sets 0 - 31 drive’s address
FLtS
Stored fault’s history - to view
scroll through stored faults F0XX to F7XX, where XX is the fault
code (section 7.3.1)
Ht
Heatsink temperature - to view
Shows heatsink temperature in ºC if greater than 40ºC. Otherwise
shows “LO” (low).
EnC
Encoder activity - to view
Shows primary encoder counts for encoder diagnostics activity
HALL
Displays motor’s hall sensor states - to view
Shows motor hall states in form XXX , where X is 1 or 0 - sensor logic
states.
buS
Displays drive DC bus voltage - to view
Shows DC bus voltage value
Curr
Displays motor’s phase current (RMS)
Shows current value if drive is enabled, otherwise shows “
DiS
”