Wiring of the standard device
l
53
EDK94ARN24 DE/EN/FR/ES/IT 2.1
I
Tip!
Parameter setting and configuration can be carried out using the
L−force »Engineer«. For this purpose the Online Help and the Software Manual
for the standard device will guide you.
System bus CAN on board
Terminal X1
Labelling
Description
Pin 2
CAN−LOW
Pin 3
CAN−GND
Pin 7
CAN−HIGH
9400SSP000X1
(Housing)
CAN−Shield
24 V supply
Terminal X2
Labelling
Description
GE
GND external supply
24E
24 V external supply via a safely separated power supply unit
(SELV/PELV)
9400SSP000X2
SB
State bus in/out (reference GE)
Terminal data
Conductor cross−section
Tightening torque
[mm
2
]
[AWG]
[Nm]
[lb−in]
Flexible
0.2 ... 2.5
24 ... 12
Spring terminal
With wire end
ferrule
Analog inputs, analog outputs
Terminal X3
Labelling
Description
GA
GND analog signals
AO1
Analog output 1
AO2
Analog output 2
A1+
Analog input 1 +
A1−
Analog input 1 −
A1−
Analog input 1 −
A1R
Terminating resistor for ±20mA
A2+
Analog input 2 +
A2−
Analog input 2 −
SSP94000X3
"
Shield connection: Fix the shield with EMC wire clamp.
Terminal data
Conductor cross−section
Tightening torque
[mm
2
]
[AWG]
[Nm]
[lb−in]
Flexible
0.2 ... 2.5
24 ... 12
Spring terminal
With wire end
ferrule