9error messages – Lenze E94AYCEC User Manual
Page 62
9
Error messages
9.2
POWERLINK error messages
62
Lenze · E94AYCEC Communication module (POWERLINK CN) · Communication Manual · DMS 3.0 EN · 08/2014 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
0x18266 98918
EL_EPL_COM_CRC
Faulty Ethernet frames (CRC error) have been detected.
Causes & remedy:
• see error description
EPL: Defective telegram (CRC) detected [0x00c88266] ( 59)
Codes:
•
/
(monitoring threshold)
•
/
(error response)
•
/
(error counter)
0x38266 229990
QL_EPL_COM_CRC
0x48266 295526
WL_EPL_COM_CRC
0x68266 426598
I__EPL_COM_CRC
0x18267 98919
EL_EPL_MN_LOSS_
CN
The MXI connection to the Servo Drive 9400 is interrupted or a node
has failed.
Causes & remedy:
• see error description
EPL: Lost connection to 9400 [0x00c83100] ( 56)
EPL: Failure of a network node [0x00c88267] ( 59)
Codes:
•
/
(error response)
•
/
(CN: link interruptions)
0x38267 229991
QL_EPL_MN_LOSS_
CN
0x48267 295527
WL_EPL_MN_LOSS_
CN
0x68267 426599
I__EPL_MN_LOSS_
CN
0x18283 98947
EL_EPL_ADDRESS_
MN
An invalid IP address has been assigned by the Managing Node via
POWERLINK or set as Node ID.
OR:
The address setting of the managing node (Node ID = ’240’) has been
assigned several times.
Causes & remedy:
• see error description
EPL: Invalid address selected [0x00c88261] ( 58)
EPL: MN address assigned double [0x00c88283] ( 60)
Codes:
Settings and displays in the »Engineer« ( 37)
0x38283 230019
QL_EPL_ADDRESS_
MN
0x48283 295555
WL_EPL_ADDRESS_
MN
0x68283 426627
I__EPL_ADDRESS_
MN
Error number
Name
Description
hex
dec