C14531 | epl tpdo, C14789 | epl number tpdo, C14880 | epl quality lights – Lenze E94AYCEC User Manual
Page 104: C14881 | epl reset error counter, Pdo mapping, C14531, 10 parameter reference
![background image](/manuals/565769/104/background.png)
10
Parameter reference
10.3
Parameters of the communication module for slot MXI2
104
Lenze · E94AYCEC Communication module (POWERLINK CN) · Communication Manual · DMS 3.0 EN · 08/2014 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
C14531
C14789
C14880
C14881
Parameter | Name:
C14531 | EPL TPDO
Data type: UNSIGNED_64
Index: 10044 = 0x273C
EPL index: See subcodes
The code describes the mapping for the TPDO channel.
describes the number of valid mapping object
entries in this code. Subcodes 1 ... 32 describe the mapping of the single objects.
Servo Drives 9400 exclusively support mapping objects with a data length of 8 bits (1 byte) or a multiple of this
value. Incompatible objects must be mapped on variables with a compatible data length.
The "Offset" (bytes 4 and 5) and "Length" (bytes 6 and 7) of the mapping object description must be a multiple of 8.
Before changing the mapping object entries in C14531,
must be set to "0". This deactivates the mapping.
with a value unequal "0" re-enables the mapping.
Offset and length of the data object relevant for the receiving EPL node must be identical with the corresponding
values of the entry in C14531.
Subcodes
Lenze setting
Info
EPL index
C14531/1
0
EPL TPDO
0x1A00.0x01
...
...
...
...
C14531/32
0
EPL TPDO
0x1A00.0x20
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C14789 | EPL number TPDO
Data type: UNSIGNED_8
Index: 9786 = 0x263A
EPL index: See subcodes
The subcode 1 describes the number of valid mapping object entries (subcodes) in code
. The value "0"
inhibits the TPDO.
Before writing a subcode of
, set C14789 subcode 1 to the value "0". Renewed writing of the number of
mapping object entries in C14789 subcode 1 enables the TPDO mapping.
Setting range
(min. value | unit | max. value)
0
32
Subcodes
Lenze setting
Info
EPL index
C14789/1
0
EPL TPDO: object count
0x1A00.0x00
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C14880 | EPL quality lights
Data type: UNSIGNED_8
Index: 9695 = 0x25DF
EPL index: not available
The code indicates the current quality status (values: 1, 2 or 4) of the network functions of the communication
module.
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT
Parameter | Name:
C14881 | EPL reset error counter
Data type: UNSIGNED_8
Index: 9694 = 0x25DE
EPL index: not available
The value "1" (TRUE) enables the code to reset the cycle counter.
After reset termination the code automatically assumes the value "0" (FALSE).
Setting range
(min. value | unit | max. value)
Lenze setting
0
1 0
Read access Write access CINH PLC-STOP No transfer PDO_MAP_RX PDO_MAP_TX COM MOT