Technical data
4.2
POWERLINK communication data
16
Lenze · E94AYCEC Communication module (POWERLINK CN) · Communication Manual · DMS 3.0 EN · 08/2014 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
4.2
POWERLINK communication data
4.2.1
Operating mode "Controlled Node"
• Support of multiplexed CNs
• Support of optional CNs
Range
Values
Jitter synchronisation information
approx. 1 s
Minimum cycle time
Controlled Node: 0.5 ms
Total cycle times
Controlled Node: 0.5 / 1.0 / 2.0 / 3.0 … 20.0 ms
Buffer size
Tx-iso: max. 92 bytes (64 bytes of PDO user data)
Rx-iso: max. 328 Bytes (300 bytes of PDO user data)
Delay times (Controlled Node)
T
Preq
- T
Res
: approx. 1 s
T
SoA
- T
ASnd
: approx. 20 s
Dead times for Managing Node
Between 2 transmission messages: min. 1 s
Between receive and transmit frame: min. 1 s
Frame size
Max. asynchronous frame size (MTU): 1518 bytes
SDO communication method
UDP/IP
Number of RPDOs
Max. 10 channels (max. 300 bytes of PDO user data per channel)
RPDO user data per application (all
RPDOs)
Max. 32 objects (max. 64 bytes)
Number of TPDOs
1 channel (data access of all nodes by broadcasting)
TPDO user data per application
Max. 32 objects (max. 64 bytes)