Led status displays of the mc-pbs, Communication card ( 48), 10 diagnostics – Lenze PROFIBUS Controller-based Automation User Manual
Page 48
10
Diagnostics
10.2
LED status displays of the MC-PBS communication card
48
Lenze · Controller-based Automation · PROFIBUS® Communication Manual · DMS 4.3 EN · 04/2014 · TD17
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _
10.2
LED status displays of the MC-PBS communication card
[10-2] LED status displays
MC-PBx-001_LED
LED
Colour
State
Description
SYS
Green
On
Communication active
(cyclic data exchange with the PROFIBUS master)
Blinking 5 times per
second (5 Hz)
No communication
(no cyclic data exchange with the PROFIBUS master)
Blinking irregularly
• Starting action: Missing or faulty configuration
• Runtime: Host watchdog time error
Yellow
Blinking once per
second (1 Hz)
The device is in bootstrap loader mode and is waiting for the
firmware download
Blinking 5 times per
second (5 Hz)
The firmware download is executed.
Blinking irregularly
A hardware or severe system error has been detected.
-
Off
No voltage supply or hardware is defective.
ST0
-
Off
No function
ST1
-
Off
No function
ST2
Red
On
The application program (bus-synchronous/device-controlled
communication mode) is no longer synchronous with the bus cycle.
Yellow
On
The slave has received parameter/configuration data from the
PROFIBUS master and is in the "DataExchange" state".
-
Off
No PROFIBUS communication
("DataExchange" state not reached)