beautypg.com

INFICON Maxtek PM-700 Plating Monitor User Manual

Page 43

background image

PM-700 SERIES PLATING MONITOR

35

Density Material

Density

Allows setting of the density
of the material being plated so
that the monitor can calculate
and display the correct
physical film thickness. A list
of the commonly used
material density is presented
in Table 21.

0.800 99.90

1.000

Acoustic
Ratio

Acoustic Ratio

Allows setting of the acoustic
impedance of the plated
material. This value is
necessary for the monitor to
accurately establish the sensor
scale factor when the sensor
crystal is heavily plated. A
list of the commonly used
material acoustic impedance is
presented in Table 21.

1.500 999.9

8.830

ElecChem ElectroChemical

Equivalent

Allows setting of the electro
chemical equivalent of the
plated material. A list of the
commonly used electro
chemical equivalent value is
presented in Table 21. Note
this value is only needed for
the electrolytic plating bath.
Therefore, this parameter is
hidden if the Type parameter
is set to Elecless (electroless).

0.000 9.999

1.000