3 test settings, 1 tooling connection, Test settings – INFICON Sensistor ILS500F Leak Detection System User Manual
Page 40

Recipes
40
ninp69e1-a (1410)
7.3
Test Settings
1
Click Settings >> Test Settings to enter the two Test Settings menus.
2
Set which steps to include in the test sequence by selecting the ON boxes.
3
Click Setup to the right of each selected step to enter the Setup menus.
7.3.1
Tooling Connection
Connection Sequence menu shows the settings made for Tooling Connection.
1
Click on the Settings symbol to edit the settings.
Test Settings
Tooling Connection
Pre Evacuation
Gross Leak Test
Tracer Gas Filling
ON
Setup
Setup
ON
Test Settings
Blockage Test
Tracer Gas Test
Gas Evacuation
Tooling Disconnection
Notice
For more information about each step, see on page 35.
Connection Sequence
Stand by
Step
Step
Step
Test
ON
ON
OFF
1
2
3
Tooling Outputs
2
3
4
1
Notice
Up to four connection steps can be programmed.