Bail handle compressed gas connectors – FasTest Bail Handle Gas Connectors User Manual
Page 4
![background image](/manuals/559789/4/background.png)
FasTest, Inc. 1646 Terrace Drive Roseville, MN 55113 Support: (800) 444-2373 Fax: (651) 645-7390 www.fastestinc.com
2
Bail Handle Compressed Gas Connectors
InstallatIon
step 1
Protect the connector from damage and dirt by keeping it in the original packaging until you are ready to use it.
step 2
Check that the connector part number and delivery notes (if applicable) comply with the application.
step 3
Connect the hose securely and leak-tight to inlet B (Figure 1). Tighten to a max torque of 15 ft-lbs.
A higher torque can result in damage causing leaks when the system is pressurized.
Ensure that the connectors cannot be damaged when loading and removing the cylinder.
step 4
Review total function:
• Check leak-tight seal
• Check if collets open and close properly by actuating
the connector several times
• Check if connector marking complies with the
application
• The
FasTest connector is ready to operate
note
Avoid lateral forces like short connecting hoses because
this could cause leakage.
Figure 1. Torque to maximum 15 ft-lb
!
CAUTION:
Do not over tighten.
Over tightening could break
connector and cause injury to operator.