InstallatIon

step 1

Protect the connector from damage and dirt by keeping it in the original packaging until you are ready to use it.

step 2

Check that the connector part number and delivery notes (if applicable) comply with the application.

step 3

Connect the hose securely and leak-tight to inlet B (Figure 1). Tighten to a max torque of 15 ft-lbs.
A higher torque can result in damage causing leaks when the system is pressurized.
Ensure that the connectors cannot be damaged when loading and removing the cylinder.

step 4

Review total function:

• Check leak-tight seal
• Check if collets open and close properly by actuating

the connector several times

• Check if connector marking complies with the

application

• The

FasTest connector is ready to operate

note

Avoid lateral forces like short connecting hoses because
this could cause leakage.

Figure 1. Torque to maximum 15 ft-lb

!

CAUTION: