beautypg.com

FasTest FasMate FX Series Rebuild User Manual

Rebuild instructions, Reassemble

background image

REBUILD INSTRUCTIONS

www.fastestinc.com

Roseville, MN
Toll Free at 1-800-444-2373
Fax 651-645-7390

WP121 Rev A 5/8/2012

LARGE O-RING

INSIDE BODY

O-RING OVER

THREADS

BACK-UP RINGS TO

THE RIGHT

BACK-UP RING

TO THE LEFT

COLLET GROOVE

LEVER

HOUSING

VALVE

HOUSING

MAIN

SEAL

REASSEMBLE:

Use all the new parts provided. Lubricate all seals with petroleum jelly.

1. Install largest o-ring inside back body. As well as exterior o-ring over the

threads.






2. Install o-rings into inner piston, making sure that o-rings and back-up rings are

located as shown.










3. Slide new spring over inner piston.
4. Slide inner piston back onto the center post of the back body.







5. Thread the pressure cap back into back body until you feel a hard stop, do not

try and over tighten. This will expose the collet groove.










6. Install main seal o-ring, back-up ring and o-ring onto piston. Slide/push piston

into inner piston.





7. Install and align collets per the spiral groove, collet numbering or both. Place

around the connector in the collet groove. Installing the collets in the proper
order is of great importance for operation of the connector. Once collets are
in place install the urethane o-ring into the groove around collets.




8. Thread sleeve onto pressure cap until hand tight.






9. Lever connector, install new dowel pins. Install new wear band onto actuator.

Slide these parts onto the back body, then thread the lever housing back onto
the back body.







10. With the Thumb Valve connector you just thread the valve housing onto the

back body.





11. Pneumatic Pilot connector, follow steps 1-8 to reassemble.



RFXxxxx Rebuild Kit for FX Style Connectors


DESCRIPTION: Rebuild Procedure for FX,
Series Connectors.



























FX with

Pneumatic Pilot

Control

FX with Lever

Control

FX with Thumb

Valve Control