2.4 Replacing a defective Slave (with teach-in of actuator)

All safety slaves with necessity for teach-in of an actuator like CES and CET can be replaced
without using a PC with ASiMon according to this method.

1. Disconnect the defective slave from AS-Interface Bus

2. Connect new slave with address 0. Close locking if necessary.

– The master addresses this slave automatically

3. Teach-in of actuator according to operation manual

4. Dissconnect new slave from AS-Interface Bus

5. Press the service button on the monitor

– The monitor stores which slave address is missing

6. Connect new slave AND bring it into a safe state

7. Press the service button on the monitor

– The monitor has a check on the safety function of the new slave