3.9 Diagnostics of slaves in Safety Monitor

1. Press OK-button

2. Select DIAGNOSIS and press OK-button








3. Select SAFETY SLAVES and press OK-button






4. Select AS-I circuit in which is the Slave and press OK-button





5. With the arrow-buttons up and down






X

=>

channel is OK

R

=>

channel has released

ON

=>

output on

OFF =>

output off

?

=>

output state unknown




1 OFF 2 OFF

3 OFF 4 OFF

PROFIBUS
QUICK SETUP
AS-I SAFETY
DIAGNOSIS
SLAVE ADR TOOL
TEST
SETUP
DISP CONTRAST

SAFETY SLAVES
INT MONITOR
EXT MONITOR
FAULT DETECTOR

SAFETY ORIENTED
SLAVES
1-

2-XX

3-RR

4-XX

5-ON

6-

AS-I CIRCUIT

1

AS-I CIRCUIT