Safety Monitors - AS-i Quick Reference - 08/2014
30
3. Select AS-I MASTER and press OK-button
4. Select AS-i CIRCUIT 1 and press OK-button
5. Read Software IDs
For analysing the fault, please write down
„SWID“, „Safe CPU-A“, „Safe CPU-B“,
„UART 1“, „UART 2“.
3.12 States of GMOX Safety Monitor
Display
LCD
AS-i-Slave-Addresses, Fault messages
LED power
Power ON
LED PROFIBUS
PROFIBUS-Master detected
LED config error
Configuration wrong
LED U AS-i
AS-i-Power OK
LED AS-i active
AS-i-operation normal
LED prg enable
Automatic slave addressing possible
LED prj mode
Project mode active
LED AUX
Auxiliary power connected
4 x LED EDM/Start
State of inputs of external feedback loop monitoring
LED off: circuit open
LED on: circuit closed
4 x LED output circuits
State of output circuits
LED off: circuit open
LED on: circuit closed
AS-I CIRCUIT
1
AS-I CIRCUIT
2
SAFETY SLAVE
INT MONITOR
EXT MONITOR
FAULT DETECTOR
DELTA LIST
LCS
ERROR COUNTERS
LPF
FLAGS
ACTUAL CONFIG
AS-I MASTER