Safety Monitors - AS-i Quick Reference - 08/2014
33
CET, TP, STP, STA, TZ, BI, all AS1
Programming: dual channel conditionally
dependent
State
Monitor diagnostics
Door closed and locked
green
Door closed and lock open
yellow blinking
Invalid state (Door open, Lock closed)
red blinking (monitoring of invalid state)
Door open
red
Address 0 or no communication
grey
CET, TP, STP, STA, TZ, BI, alle AS1
Programming: dual channel independent
State
Monitor diagnostics
Door closed and locked
green
Door closed and lock open
red
Invalid state (Door open, Lock closed)
red (no monitoring of invalid state)
Door open
red
Address 0 or no communication
grey
CET, TP, STP, STA, TZ, BI, alle AS1
Programming: dual channel dependent,
Synchronization time
∞
State
Monitor diagnostics
Door closed and locked
green, when door was open before or after startup
yellow blinking, when only lock was open
Door closed and lock open
yellow blinking, when door was close before
red, when door was open before
Invalid state (Door open, Lock closed)
yellow blinking, when door was close before
red, when door was open before
Door open
red
Address 0 or no communication
grey