3.7 Replacing a defective AS-i Safety Monitor


If an AS-i Safety Monitor is defective and needs to be replaced, the replacement unit does
not necessarily have to be newly configured using the ASIMON software, and rather it is
possible to copy the configuration of the defective device using a chip card.

If the card and device are not empty at start and the data are not identical, an error message
is displayed and the card is not synchronized with the device. The following menu is then
automatically opened:






Command

Description

CHIPCARD > MASTER

Chip card data are copied to the master

MASTER -> CHIPCARD

Master data are copied to the chip card

CONTINUING

No change to the data



To choose the menu manually:

1. Press OK-button


2. Select AS-I SAFETY and press OK-button










1 OFF 2 OFF

3 OFF 4 OFF

CHIPCARD AND
AS-I DATA
DIFFERENT
CHIPCARD -> MASTER
MASTER -> CHIPCARD
CONTINUING

PROFIBUS
QUICK SETUP
AS-I SAFETY
DIAGNOSIS
SLAVE ADR TOOL
TEST
SETUP
DISP CONTRAST