Det-Tronics R8471NH34001,2,3 Single Channel Gas Controller, NH3 User Manual
Page 25

23
95-8529
1.1
REPLACEMENT PARTS
The controller is not designed to be repaired by the
customer in the field. If a problem should develop,
first carefully check for proper wiring, programming
and calibration. If it is determined that the problem is
caused by an electronic defect, the device must be
returned to the factory for repair.
NOTE
When replacing a controller, be sure that
the jumper plugs and rocker switches of the
replacement are the same as the original.
Remove power before removing the controller
from the mounting cage or plugging in the
replacement unit.
ORDERING INFORMATION
Sensors must be ordered separately from the
controller. When ordering please specify:
R8471D Cl
2
Controller
R8471F SO
2
Controller
R8471G NO
2
Controller
Specify base or premium model, 3U or 4U height.
MOUNTING RACKS
A mounting rack is required for controller installation.
3U racks are used with gas controllers only. 4U
racks can house gas or flame controllers in any
combination. See Figures 8 and 9.
SENSOR/TRANSMITTER
Part Number
Description
005931-001 C7067E
(Cl
2
) Sensor Housing with
3/4 inch entry
005931-002 C7067E
(Cl
2
) Sensor Housing with 20
mm entry
005932-001
Electrochemical Sensor Cell for
C7067E (Cl
2
)
006398-001 C7068E
(SO
2
) Sensor Housing with
3/4 inch entry
006398-002 C7068E
(SO
2
) Sensor Housing with
20 mm entry
006400-001
Electrochemical Sensor Cell for
C7068E (SO
2
)
006394-001 C7069E
(NO
2
) Sensor Housing with
3/4 inch entry
006394-002 C7069E
(NO
2
) Sensor Housing with
20 mm entry
006395-001
Electrochemical Sensor Cell for
C7069E (NO
2
)
CALIBRATION EQUIPMENT
Part Number
Description
227115-013 Cl
2
Calibration Kit, includes regulator,
hose, calibration cup, and two
cylinders of calibration gas (5 ppm).
227115-012 SO
2
Calibration Kit, includes
regulator, hose, calibration cup, and
two cylinders of calibration gas (50
ppm).
227115-011 NO
2
Calibration Kit, includes
regulator, hose, calibration cup, and
two cylinders of calibration gas (10
ppm).
REPLACEMENT PARTS
Part Number
Description
227117-006 Replacement cylinder of gas for Cl
2
calibration kit (5 ppm)
227117-008
Replacement cylinder of gas for SO
2
calibration kit (50 ppm)
227117-010
Replacement cylinder of gas for NO
2
calibration kit (10 ppm)
For assistance in ordering a system to meet the needs
of a specific application, please contact:
Detector Electronics Corporation
6901 West 110th Street
Minneapolis, Minnesota 55438 USA
Operator: (952) 941-5665 or (800) 765-FIRE
Customer Service: (952) 946-6491
Fax: (952) 829-8750
Web site: www.det-tronics.com
E-mail: [email protected]