Maintenance, Tool – BAND-IT UL4000-B Cordless Ultra-Lok Tool User Manual
Page 12
BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street
Denver, CO 80216-0307 USA
P: 1-800-525-0758
F: 1-800-624-3925
Document # P07986 Rev. F
© Copyright
BAND-IT-IDEX, Inc. 2011
All rights reserved
www.BAND-IT-IDEX.com
Page 12 of 14
UL4000-B
UL4000-B220
Ultra-Lok
Tool
Maintenance
1. Approximately every 500 clamps lubricate Tension Screw with
molybdenum disulfide lubricant, or equivalent.
Make sure Tension Block is all the way forward against the Tool Head.
Remove cap from syringe and insert tip of syringe into slot on top of tool body.
Press the tip against the Tension Screw just behind the Tension Block and
squeeze out approximately 1/2" long bead of lubricant. Remove Syringe, and
actuate tool without a clamp a couple of times to spread lubricant evenly on
tension screw.
To order more lubricant, specify BAND-IT #C23199
3. To gain access to bearing components: remove blade Mounting Screws (2
places) and slide Blade free. Paper clip may be used to push bearing
components out of Blade. Wipe lubricant from components. If ball or bearing
tips appears heavily worn, replace with new one. Note: 1/4" ball is made from
hard tungsten carbide material, do not replace with regular ball bearing.
(Smooth indention from ball in the bearing tips is normal).
To re-assemble bearing components: wipe blade cavity clean. Push small
bearing tip into blade cavity. Apply lubricant to ball and push into Blade cavity
and fill remaining space with lubricant. Push load bearing tip firmly into blade
cavity, some lubricant will be squeezed out. Re-attach blade to Tool Head,
making sure that load bearing tip extends into Tension Screw. While turning
Blade Mounting Screws into Blade, push on Blade rear-wards. Tighten
screws to approximately 120 in-lbs.
4. When replacing worn Blade follow instructions above to properly re-
assemble bearing components.
2. Every 500-1000 clamps, depending on torque setting, inspect and
repack front bearing with same lubricant. Turn load bearing tip and small
bearing tip over for a new bearing surface.
Small Bearing Tip
M05387
1/4" Ball
M06587
Load Bearing Tip
M02287
Access Hole to push
out components (use
paper clip)
Blade
M09787
Blade Cavity,
must be packed
with lubricant
Tension
Screw
M00987
Bearing Detail
Blade Mounting
Screws
M05787
Tool
Body
Tool
Head
Item 1
Lubricating Syringe
Reorder #C23199