beautypg.com

Clamp application free-end clamps, Tool – BAND-IT UL4000-B Cordless Ultra-Lok Tool User Manual

Page 10

background image

BAND-IT-IDEX, Inc.
A Unit of IDEX Corporation
4799 Dahlia Street
Denver, CO 80216-0307 USA
P: 1-800-525-0758
F: 1-800-624-3925

Document # P07986 Rev. F

© Copyright

BAND-IT-IDEX, Inc. 2011

All rights reserved

www.BAND-IT-IDEX.com

Page 10 of 14

UL4000-B

UL4000-B220

Ultra-Lok

Tool

Clamp Application
Free-End Clamps


Inspect buckle on completed clamp and tap down buckle shroud.







































FRONT VIEW

Completed Free-End Clamp

(Visually inspect lock)

Buckle Shroud

Lock sheared in center
and formed inside
shroud

SIDE VIEW

Completed Free-End

Clamp

Tap down buckle shroud to
complete clamp

Completed clamp
should appear as
shown.

Important: Visually inspect lock formed in band as shown. If lock has slipped under the sheared surface of the
buckle, remove clamp and install a new one at reduced tension by lowering the Drill Clutch torque setting.

Shear Surface

Section View

Good Clamp

Bad Clamp

Lock has slipped back
under sheared buckle
surface