beautypg.com

It5000-ab, Troubleshooting matrix, 20 of 38 – BAND-IT IT5000-AB 3/8 Junior Tool User Manual

Page 20: 3/8” junior, Tool

background image

Document # I17795 Rev G

© Copyright

BAND-IT-IDEX, Inc. 2009

All rights reserved

www.BAND-IT-IDEX.com

BAND-IT-IDEX, Inc.

A Unit of IDEX Corporation

4799 Dahlia Street Denver, CO 80216-0307 USA

P: 1-800-525-0758 F: 1-800-624-3925

20 of 38

IT5000-AB

3/8” Junior

®

Tool

Symptom

Probable cause

Recommended Fix

Page

Control Module air pressure
valve is in "off" position.

Rotate Control Module shut-off valve to open position.
Verify that gauges read air pressure and check all
connections for air leaks.

5

Clamp tail inside tool

Remove clamp tail, if jammed remove
maintenance/flip cover and remove clamp material.

15-17

Knife is in down position.

Remove or replace knife. Verify missing and or
damaged linkage.

23

Wrong clamp type for tool

Verify proper tool for selected clamp.

Cover Page

Handle will not

adjust

Handle nut is
damaged/misaligned.

Remove handle assembly and inspect nut/housing for
damage. Replace as required.

9

Clamp will not

insert into tool

* = for additional assistance, contact BAND-IT

Troubleshooting
Matrix