IT5000-AB
3/8” Junior
®
Tool
Tool fails to cut off clamp tail:
• The Inlet Air Pressure may be low. Check air supply to Air Controller Module. Cut-off
Pressure Gauge should indicate 100-110 PSI (690-760 kPa). See pages 4-6 for air supply
requirements.
• The scrap clamp tail from the previous clamp may not have been removed. Press the Reset
Button to release the tension on the clamp and remove the clamp tail scrap.
• The Cutter Blade or Knife may be worn. See below for Cutter Blade inspection and
replacement.
• Note: The Flip Cover Tightening Screw and Flip Cover Head Screws are factory tensioned
and will need to have thread locking compound reapplied and be re-tensioned after the quick
release pins are reinstalled upon completion of maintenance.
2. Remove Flip
Cover and Tension
Block Assembly for
cleaning and
lubrication.
3. Remove the Cutter
Blade Pin and Cutter
Blade. The Cutter
Blade has two working
edges and can be
rotated 180
° to use the
second edge prior to
replacement.
4. When installing
the Cutter Blade
Pin, use a small
screwdriver to
push the front
gripper toward the
back of the tool.
1. Loosen the Flip
Cover Tightening
Screw and Flip Cover
Head Screws (see
note above) to remove
both Quick Release
Pins as shown.
Cutter Blade inspection and replacement:
Front
Gripper
Cutter
Blade Pin
Troubleshooting