IT5000-AB
3/8” Junior
®
Tool
Clamp Installation:
When installing a clamp, a random visual check to verify the presence of a locking lip
after the clamp has been applied is recommended. The lip is the locking element of
an installed clamp. The IT5000 forms a fold of band at the buckle edge with the
knife. By controlling and monitoring the items that are needed to form a good lock,
an operator can help insure that the band will be applied correctly without having to
inspect every assembly.
These items are:
•Adequate air pressure and volume (see page 4,6)
•Setting the tool air pressure (see page 4,6)
•Following recommended PM Schedule (see page 21)
•Fixture mounting the tool properly (see page10-13 )
For best performance and to extend tool life:
• Follow preventative maintenance and parts replacement instructions
(page 21) at appropriate service intervals.
• Do not remove factory applied lubrication from inside tool unless performing a
thorough maintenance procedure and then replacing with fresh lubricant
immediately.
• Do not use degreaser inside the tool body.
• Do not spray any lubricant or cleaner into the Quick Connect Air Couplings.
• Use nominal recommended tension setting (listed on page 4,6). Higher pressure
may not result in a tighter clamp, but increases the likelihood of clamp tail jamming
and premature worn parts.
• Do not over-tighten Knife Pin access screws. Over tightening of these screws may
result in stripping screw threads.
• For maintenance beyond what is described in this manual, consult BAND-IT.