IT5000 Configured for Remote Actuation:
•
The IT5000 with trigger option 1 and is a modified version of the base unit. A tool with trigger option 0 is
manually operated via the incorporated thumb actuation lever. A tool with trigger option 1 is configured to
allow remote operation via palm button or other device permitting the tool to be incorporated into the
customer’s fixture or assembly process.
•
The modification consists of deactivating the thumb lever actuation switch and installing two 6-
ft X 1/8”
O.D. hoses to accomplish the same task via the use of a remote actuation device such as a palm button
or other device that can provide a pneumatic signal to pilot the tension control valve.
•
Various actuation devices can be incorporated based upon end user requirements. Basic schematic for 2-
way & 3-way valves included below. The valve should be set up in the normally closed mode and upon
opening the circuit a supply of air is provided.
•
The customer is responsible for incorporating this tool into their process, BAND-IT is available to provide
advice and recommendations.
Remote trigger: 2-way valve
Supply Hose from
tool 90-120 PSI
(female quick disconnect)
Hose from tool
(male quick disconnect)
Actuate
to start
tool
Actuate
to stop
tool
Remote trigger: 3-way valve
Supply Hose from
tool 90-120 PSI
(female)
Hose from
tool (male)
Actuate to
start tool
Actuate to
stop tool
Hose from tool
(male)
Supply Hose from
tool 90-120 PSI
(female)
If more than one trigger is used,
connect in series. All need to be
actuated to run the tool.
Multiple Triggers
Connect the 2 hoses extending
from the tool to the ports of the
valve. As the hoses are not
marked, they may need to have
their connection on the valve
reversed if the remote trigger
does not start the tool.