Button:
• Resets relay 1
• Program change

(hold for 3 seconds)

Red indicator:
• Reading out-of-range
• Wrong tool version connected Yellow indicator:

• No tool connected
• Error in cut-off cycle

Overview of Data Control Box

Green indicator:
• Ready to monitor tool
• No errors

BAUD selection switch

Relay contacts
12VDC 500mA max

Relay1, closes on:
• Out-of-range reading

Relay2, closes on:
• Clamp cycle completion

Tension Cylinder
Pressure Monitoring
System