Lubrication
– Follow recommended intervals – Use a synthetic gel lubricant containing
Teflon for the internal parts as shown and described. Lubricate all pivot points and internal
surfaces of maintenance flip cover with a light coating of the lubricant.
Caution
– Excessive amounts of lubricant may result in gripper slippage, requiring a
full repeat of cleaning process.
Tool mechanics
every 25,000 cycles
Lightly lubricate all
points indicated with
red arrows.
Tension Block Assembly
every 12,500 cycles
Note: Ensure no
lubrication is present in
the center of Gripper.
(indicated by the
blue
circle
)
Maintenance Flip Cover
every 12,500 cycles
After the Maintenance
Flip Cover is cleaned,
lubricated, installed and
Quick Release Pins are
in place, apply tension
to the Flip Cover Screw
and Head Screws.
Refer to pages 7, 17.