5.2 – CAN Connection
In case of a CAN connection with only one LCU-ONE, follow the scheme shown above.
Use extensions labelled as “1” and “2” to make CAN connections with AIM loggers that
support it. It is reminded to use the proper cap indicated in the figure above (“CAN
termination”) to terminate CAN line.
It is suggested to insert a 5 A fuse for each controller in series between external battery
and LCU-ONE to protect the system.
Refer to this tutorial appendix to know items part number and connectors pinout.
LCU-ONE, like the logger, needs to be powered by the vehicle master switch.
As far as the connections with the loggers are concerned refer to each logger
user manuals.
Warning: connect LCU-ONE to AIM loggers OFF