Call termination (outgoing and incoming calls), Function description 4.1 – 2N Lift emergency phone 2N SingleTalk - Manual, 1514 v6.3.0 User Manual
Page 62

Function Description
4.1
61
Talk or silence
The ST waits for a defined timeout (logon time),
then hangs up and dials the following number
Continuous tone (PBX)
The ST hangs up in approximately 2 seconds and
dials the following number
Ringing tone is terminated before
10 rings (or as programmed) are
reached
This is considered as a successful call, the call
continues for the defined period of time (maximum call
time). The message is played back once.
Ringing tone with 10 rings (the
count can be defined)
The ST hangs up and dials the following number
to
,
These digits are interpreted as the switch control
password beginning
Dialing type 3 hangs up and calls next number,
Dialing type 4 hangs up and stops calling.
valid switch password
(switch activation)
Dialing type 4 consider such call as a successfull,
even if ringing tone is not detected.
Warning
Be sure to disable your voice mailbox, fax machine or any other
equipment connected to the called numbers to avoid premature
answering. This would terminate the dialing automatically.
Call Termination (Outgoing and Incoming Calls)
The busy or continuous tone*) is detected (for PBX call termination).
10 ringing tone*) periods are detected (for a change use parameter 954).
This is an innovation compared with the earlier model.
The maximum call length has elapsed – the ST plays back the “Attention,
your call is being terminated” message 10 seconds before the end; the call may
be prolonged.
vyprší nastavená maximální délka hovoru – 10 sekund před vypršením ST
přehraje hlášení „Pozor, končí hovor“, hovor lze prodloužit.
The
or
character is received.
The timeout has expired during programming, or upon message recording.
30 seconds after switch activation.
The same button is pressed during an outgoing call that was used for making
the call (this function is disabled in the lift version).
Note
The ST is able to detect the continuous, busy and ringing tones even if the
tone has two frequency components as the case is in the UK and USA
(BTT) and in Canada. This new function requires no parameter. One of the
tone components must be 440 Hz