Review of programming functions 3.2 – 2N Lift emergency phone 2N SingleTalk - Manual, 1514 v6.3.0 User Manual
Page 57

Review of Programming Functions
3.2
56
Function
Number and Name
Value Range
Initializa-
tion Value
Notes, Explanations
981 – checking call
0 – disabled
1 – enabled
0
0 = off
1 = checking call in 1 minute; if previously off, the
checking call is enabled and the 3-day period
initialization is executed.
2 = on, first call in 2 hours
3 = on, first call in 3 days
Note: The voice menu recognises states 0 and 1 only,
but you may also enter values 2 and 3 to set the first
checking call time. The time that is left before the next
checking call is not announced in the voice menu.
991 – service password
up to 16 digits
12345
995 – software version check
-
This function spells present version of software.
Format: year-month-day
997 – password initialization for
all switches
enter the
service
password
The execution of these commands takes a rather
long time, typically approx. 5 seconds and 30
seconds at most. The ST is sending the
continuous tone while deleting the memory. Re-
enter the valid service password as the function
parameter (as protection against unintended
deletion if you enter a false function number).
998 – dialing memory deletion
for all buttons
enter the
service
password
999 – full initialization (incl.
service password!)
enter the
service
password
1
)
To parameter 904: The Automatic dialing without confirmation types 3 and (newly) 4
differ from each other in processing very short calls. Dialing 4 regards a call as successful
in all cases while dialing 3 only if the switch was activated. Since the switch is not
practically used for the ST, this difference is irrelevant.
2
)
A new implicit value, a lower probability of unintentional detection.
3
)
In the event of automatic dialing without confirmation, the ringing tone is detected and
terminated before the selected count of periods is reached, the call is regarded as
successful.
Note
Unless the ST is damaged electrically, the EEPROM guarantees 10 years of reliable
data storing at least.