Review of Programming Functions

3.2

53

Function
Number and Name

Value Range

Initializa-
tion Value

Notes, Explanations

811

821

Switch 1,2,3 password

addition

up to 16 digits

00

Adds another password to the list. The password
may not be identical with any other password;
otherwise it is rejected. Password 00 may not be
entered from a keyboard. Each switch can have up
to 10 passwords.

11

812

822

832

Switch 1,2,3 password

removal

Valid password

Removes a password from the list.

WARNING! Remember to cancel password 00
with this function if you do not intend to use it!

Forgotten passwords can be removed by
initialization only.

813

823

833

Switch 1,2,3 activation

time

0–9 (seconds)

5 s

0 = the switch is out of operation

901 – dialing type

0 or 1

0 = tone

1=pulse 40/60

902 – dialing start time

(after pick-up)

5 to 99

corresponds to

0.5 to 9.9 s

33 =

3.3 seconds

Time between pick-up and dialing start.

Do not set time less than 2.7 s as required by
the TBR-21 standard.

903 – DTMF level

0–12

6

1 step = 1 dB

904 – automatic dialing type

0–4

1

0 = disabled for all buttons
1 = loud dialing with confirmation
2 = silent dialing with confirmation
3, 4 = loud dialing without confirmation

1

)

911 – number of rings until

incoming call answering

1–99

2

Defines the moment of pick-up during ringing.
ATTENTION! Select 1 if connected to Lift Call
Connect, Order. No. 91330808E!

912 – maximum call duration

1 to 99

corresponds to

10 to 990 s

12 =

2 minutes

06 = 1 minute, 30 = 5 minutes, 99 = 16.5 minutes

The call can be prolonged by pressing

.

913 – seizure timeout

(for automatic dialing)

1–99

corresponds to

10 to 990 s

6 = 60

seconds

change!

The maximum time, during which the dispatcher
has to answer and send confirmation, otherwise
the ST hangs up and dials the following number.
Starts at the dialing end.

914 – delayed calling

0–9

(count of

cycles)

0 = no

delay

change!

applies to button 01 only

915 – hang-up timeout

between calls

5–99

corresponds to

0.5 to 9.9 s

55 = 5.5 s

Do not set time less than 5 s as required by the
TBR-21 standard.

916 – CANCEL input inversion

0 or 1

0

0 = contact closed (or voltage present) at open
door,
1 = contact closed (or voltage present) at
closed door.