Free minutes bank, Table of parameters 3.2 – 2N Analogue GSM gateway 2N EasyGate PRO - Manual, 1749 v1.03 User Manual
Page 39

Table of Parameters
3.2
39
for example received CLI +420603198222 corresponds with settings:
CLI - calling number
Substring
+420603198222
any setting
+420603
any setting
+420
any setting
603198222
4, or more
603
4, or more
Setting options:
0-15
Step:
1
Default setting:
0
Route to
Function No.: 591
It is possible to route incoming call from mobile network to FXS interface or
reject it. When the call is routed to FXS port you can use the CallBack feature.
For correct functionality please set up "Max. ring time for Callback" parameter.
Setting options:
FXS (0) -incoming call is routed to FXS
FXS CallBack (2) -incoming call is routed to FXS with
CallBack functionality
Reject (4) -incoming call is rejected
Default setting:
FXS
Dial in
Function No.: 592
Parameter "Dial in" is used for automatic connection to switchboard operator, or
directly to other subscriber. If this parameter is blank, calling person has
telephone line fully at disposal and has to dial the subscriber number by DTMF.
You can fill only # character to disable Dial in function.
Setting options:
0-16 characters (0-9,*,#)
Default setting:
blank
Time limit [min]
Function No.: 599
After time elapsing is call connection terminated immediately. You can hear beep
30s before end of call. 10s before end you can hear beep every second. The "0"
setting means that the function is disabled.
Setting options:
0-255 min
Setting step:
1 min
Default setting:
0 min
Free minutes bank
See section 4.6 for detailed description. This option can be used with Firmware 3.5x
only.