beautypg.com

JLG 601S ANSI Service Manual User Manual

Page 39

background image

SECTION 2 - GENERAL

3120746

– JLG Lift –

2-13

Walk-Around Inspection Performed

21

Annual Machine Inspection Due

21

No Unauthorized Modifications or Additions

21

21

All Relevant Safety Publications Incorporated

21

21

General Structural Condition and Welds

2,4

2,4

All Fasteners, Pins, Shields, and Covers

1,2

1,2

Grease and Lubricate to Specifications

22

22

Function Test of All Systems

21

21

21, 22

Paint and Appearance

7

7

Stamp Inspection Date on Frame

22

Notify JLG of Machine Ownership

22

Footnotes:

1

Prior to use each day; or at each Operator change

2

Prior to each sale, lease, or delivery

3

In service for 3 months or 150 Hours; or Out of service for 3 months or more; or Purchased used

4

Annually, no later than 13 months from the date of the prior inspection

Performance Codes:
1 - Check for proper and secure installation
2 - Visual inspection for damage, cracks, distortion or excessive wear
3 - Check for proper adjustment
4 - Check for cracked or broken welds
5 - Operates Properly
6 - Returns to neutral or "off" position when released
7 - Clean and free of debris
8 - Interlocks function properly
9 - Check for signs of leakage
10 - Decals installed and legible
11 - Check for proper fluid level
12 - Check for chafing and proper routing
13 - Check for proper tolerances
14 - Properly lubricated
15 - Torqued to proper specification
16 - No gouges, excessive wear, or cords showing
17 - Properly inflated and seated around rim
18 - Proper and authorized components
19 - Fully charged
20 - No loose connections, corrosion, or abrasions
21 - Verify
22 - Perform
23 - Sealed Properly
24 - Drain, Clean, Refill

Table 2-3. Inspection and Preventive Maintenance Schedule

AREA

INTERVAL

Pre-Start

1

Inspection

Weekly

Preventive

Maintenance

Monthly

Preventive

Maintenance

Pre-Delivery

2

or Frequent

3

Inspection

Annual

4

(Yearly)

Inspection

Every 2

Years