beautypg.com

Procedure, Controller status, Failure modes – JLG 601S ANSI Service Manual User Manual

Page 104: Addco adjustments - deutz -64

background image

SECTION 3 - CHASSIS & TURNTABLE

3-64

– JLG Lift –

3120746

Procedure

NOTE: Never run fuel tank dry. Diesel engines cannot be

restarted after running out of fuel until fuel system
has been air-vented or bled of air. See Deutz Instruc-
tion Manual for procedure.

1. Power the ignition switch at the ground control

panel. Set the mid rpm.

2. Supply 12 volts of power to the white wire on the

controller. Set the high engine rpm.

NOTE: Actuator rod travel must stop slightly before lever

makes contact with throttle lever stop. Failure to do
so will burn out actuator.

Controller Status

Clutch engaged no actuator movement

Clutch engaged actuator extending

Clutch engaged actuator retracting

Controller fault - clutch disengaged and no actuator
movement

Failure Modes

Immediate Red Light

Action:

1. Recycle power to determine if the problem is inter-

mittent.

2. The input voltage must be greater than 10.5 Vdc.

3. Check wiring for any damage and correct.

4. Disconnect engine harness and actuator connnec-

tions.

5. If problem reoccurs return unit.

HIGH#2

MID #1

CCW EXTEND
ACTUATOR
(HIGHER)

CW

CCW

Figure 3-44. Addco Adjustments - Deutz