beautypg.com

9 analyzer diagnostics menu structure, Analyzer diagnostics menu structure -44, Adjustments - personality descriptions -44 – JLG 601S ANSI Service Manual User Manual

Page 218

background image

SECTION 6 - JLG CONTROL SYSTEM (ADE)

6-44

– JLG Lift –

3120746

6.9 ANALYZER DIAGNOSTICS MENU

STRUCTURE

In the following structure descriptions, an intended item is
selected by pressing ENTER; pressing ESC steps back to

the next outer level. The LEFT/RIGHT arrow keys move
between items in the same level. The UP/DOWN arrow
keys alter a value if allowed

Table 6-7. ADJUSTMENTS - Personality Descriptions

DRIVE

ACCEL …

Displays/adjusts drive acceleration

DECEL …

Displays/adjusts drive deceleration

MIN FORWARD …

Displays/adjusts minimum forward drive speed

MAX FORWARD …

Displays/adjusts maximum forward drive speed

MIN REVERSE …

Displays/adjusts minimum reverse drive speed

MAX REVERSE …

Displays/adjusts maximum reverse drive speed

ELEVATED MAX …

Displays/adjusts maximum drive speed
NOTE: used when elevation cutout switches are limiting maximum speed

CREEP MAX …

Displays/adjusts maximum drive speed
NOTE: used when creep switch on pump pot is active

STEER MAX …

Displays/adjusts the maximum steer speed

LIFT

ACCEL …

Displays/adjusts upper lift acceleration

DECEL …

Displays/adjusts upper lift deceleration

MIN UP …

Displays/adjusts minimum upper lift up speed

MAX UP …

Displays/adjusts maximum upper lift up speed

CREEP UP …

Displays/adjusts maximum upper lift up speed
NOTE: used when creep switch on pump pot is active

MIN DOWN …

Displays/adjusts minimum upper lift down speed

MAX DOWN …

Displays/adjusts maximum upper lift down speed

CREEP DOWN …

Displays/adjusts maximum upper lift down speed
NOTE: used when creep switch on pump pot is active