beautypg.com

JLG 601S ANSI Service Manual User Manual

Page 201

background image

SECTION 6 - JLG CONTROL SYSTEM (ADE)

3120746

– JLG Lift –

6-27

4/4

Flash code 4/4 indicates problems with the battery supply. Not
reported during 2 second power-up.

7

BATTERY LOW

Battery voltage is below 11V for more than 5 seconds. This fault is not
detected during crank. This is a warning – the controller does not shut
down.

BATTERY TOO HIGH – SYS-
TEM SHUT DOWN

Battery voltage is above 16V. EMS recycle required.

BATTERY TOO LOW – SYS-
TEM SHUT DOWN

Battery voltage is below 9V.

5/5

Flash code 5/5 indicates problems with vehicle engine RPM or the
encoder. Not reported during 2 second power-up.

8

SPEED SENSOR READING
INVALID SPEED

This fault is detected with diesel engines only. The RPM pickup is indicat-
ing a speed that greater than 4000 RPM or approximately 8875 Hz.

SPEED INPUT LOST

This fault is detected with diesel engines only. It occurs if there is no RPM
detected and the oil pressure input is reading above 8 PSI for more than
three seconds. This is probably due to wiring problems at the ground mod-
ule or a faulty speed sensor.

6/6

Flash code 6/6 indicates problems with the CAN bus.

10

CAN BUS FAILURE:

The ground module or platform module is not receiving CAN messages.
This is probably due to wiring problems between the platform and ground
modules.

7/7

Flash code 7/7 indicates problems with a motor.
NOT REQUIRED

9/9

Flash code 9/9 indicates problems with the controller.

11

PLATFORM MODULE SOFT-
WARE UPDATE REQUIRED

Platform module code is too old to support the EIM or BPE load sensor and
the machine is configured to use one of these two sensors. The PM code
must be updated to a newer version.

HIGH RESOLUTION A2D FAIL-
URE –INTERRUPT LOST

The ADS1213 chip in the platform module has stopped asserting its inter-
rupt (DRDY) line for some reason. An EMS cycle is required.

HIGH RESOLUTION A2D FAIL-
URE-REINIT LIMIT

The ADS1213 has needed to be reset 3 or more times.

PLATFORM MODULE FAIL-
URE: hwfs CODE 1

Platform module V(Low) FET has failed

GROUND MODULE FAILURE:
hwfs CODE 1

Ground module V(Low) FET has failed

GROUND SENSOR REF
VOLTAGE OUT OF RANGE

These faults occur when the seven volt reference voltage used for the joy-
sticks, sensors, etc. goes out of range. Not reported during 2 second
power-up.

PLATFORM SENSOR REF
VOLTAGE OUT OF RANGE

These faults occur when the seven volt reference voltage used for the joy-
sticks, sensors, etc. goes out of range. Not reported during 2 second
power-up.

EEPROM FAILURE – CHECK
ALL SETTINGS

A critical failure occurred with the EEPROM. Personalities, machine con-
figuration digits, etc. may be reset to default values and should be
checked.

Table 6-3. Help Fault Codes, Displayed Faults, and Descriptions - S/N 66939 to Present

Fault Flash

Code

Communicated (Displayed on

Analyzer) Fault

Description

Priority