Electrical System
9-90
3508PS, 3509PS, 3512PS, 3513PS, 4008PS, 4009PS, 4012PS, 4013PS, 4017PS, 40.8, 40.9
LSI DETECTED BUT
NOT CONFIGURED
8515
1
Inhibit all hydraulic functions.
Set CAN message bit to permit LSI
System display control of its alarm.
The UGM has detected the CAN
bus LSI system is present on the
machine; however it has not been
configured properly in the
MACHINE SETUP - LOAD
MOMENT menu selection.
Use analyzer
and correct
parameter
that is
improperly
configured.
LSI LOAD CELL A –
OUT OF RANGE
8516
1
If active, the control system will
respond as if the Load Moment
Cutout % parameter has been
reached and react accordingly
depending on the MARKET
configuration.
Set CAN message bit to permit LSI
System display control of its alarm.
The LSI System has detected that
Load Cell A is out of range and is
providing a CAN bus message
notification to the UGM.
Power cycle.
LSI LOAD CELL B –
OUT OF RANGE
8517
1
If active, the control system will
respond as if the Load Moment
Cutout % parameter has been
reached and react accordingly
depending on the MARKET
configuration.
Set CAN message bit to permit LSI
System display control of its alarm.
The LSI System has detected that
Load Cell B is out of range and is
providing a CAN bus message
notification to the UGM.
Power cycle.
LSI CUTOUT
OUTPUT – SHORT
TO BATTERY OR
OPEN CIRCUIT
8518
1
If active, the control system will
respond as if the Load Moment
Cutout % parameter has been
reached and react accordingly
depending on the MARKET
configuration.
Set CAN message bit to permit LSI
System display control of its alarm.
The LSI System has detected that
its 100% Cutout digital output has
an short to battery or open circuit
condition and is providing a CAN
bus message notification to the
UGM.
Power cycle.
LSI OUT OF
CALIBRATION
8519
1
If active, the control system will
respond as if the Load Moment
Cutout % parameter has been
reached and react accordingly
depending on the MARKET
configuration.
Set CAN message bit to permit LSI
System display control of its alarm.
The UGM LSI-CAN system check
has been performed and the actual
load cell raw counts are not within
+/- 10 counts of the logged
calibrated counts.
The LSI-CAN
system check
is performed
and is
completed
with a pass
condition.
STEERING
86XXX
LOW STEERING
PRESSURE
8638
1, 8
N/A
J1-35 Steering Pressure is HIGH for
a period of 3 seconds or more and
an ENGINE RUNNING state must
be detected for at least 5 seconds.
Until steer
pressure is
re-estab-
lished (i.e.
J1-35 is LOW
for a period of
3 seconds).
HARDWARE
99XXX
LSS WATCHDOG
RESET
991
1
Power
cycle.
(Replace
board)
Message
Fault
Code
Indicators
Other Actions Taken
Trigger for Fault
Latch Until