beautypg.com

Electrical system – JLG 4013PS Service Manual User Manual

Page 207

background image

9-67

3508PS, 3509PS, 3512PS, 3513PS, 4008PS, 4009PS, 4012PS, 4013PS, 4017PS, 40.8, 40.9

Electrical System

HYDRAULIC QUICK
CONNECT SELECT
– OPEN CIRCUIT

33204

1

Deactivate output J1-23 Hydraulic

Quick Connect Select.

If hydraulic quick connect feature is

configured in the MACHINE SETUP

menu and the UGM detects an

open circuit at this output.

Power cycled.

HYDRAULIC QUICK
CONNECT SELECT
– SHORT TO
BATTERY

33205

1

Deactivate output J1-23 Hydraulic

Quick Connect Select.

Deactivate output J2-9 Auxiliary

Function-A Valve.

Deactivate output J2-20 Auxiliary

Function-B Valve.

If hydraulic quick connect feature is

configured in the MACHINE SETUP

menu and the UGM detects a short

to battery at this output.

Power cycled.

HYDRAULIC QUICK
CONNECT SELECT
– SHORT TO
GROUND

33206

1

Deactivate output J1-23 Hydraulic

Quick Connect Select.

Deactivate output J2-9 Auxiliary

Function-A Valve.

Deactivate output J2-20 Auxiliary

Function-B Valve.

If hydraulic quick connect feature is

configured in the MACHINE SETUP

menu and the UGM detects a short

to ground at this output.

Power cycled.

HORN –
OPEN CIRCUIT

33207

1

Deactivate output J2-2 Horn.

The UGM detects an open circuit at

this output.

Power cycled.

HORN – SHORT TO
BATTERY

33208

1

Deactivate output J2-2 Horn.

The UGM detects a short to battery

at this output.

Power cycled.

HORN – SHORT TO
GROUND

33209

1

Deactivate output J2-2 Horn.

The UGM detects a short to ground

at this output.

Power cycled.

REVERSE ALARM
AND LIGHTS –
OPEN CIRCUIT

33210

1

Deactivate output J1-1 Reverse

Alarm and Lights.

The UGM detects an open circuit at

this output.

Power cycled.

REVERSE ALARM
AND LIGHTS –
SHORT TO
BATTERY

33211

1

Deactivate output J1-1 Reverse

Alarm and Lights.

The UGM detects a short to battery

at this output.

Power cycled.

REVERSE ALARM
AND LIGHTS –
SHORT TO
GROUND

33212

1

Deactivate output J1-1 Reverse

Alarm and Lights.

The UGM detects a short to ground

at this output.

Power cycled.

DUMP VALVE –
OPEN CIRCUIT

33213

1

Deactivate output J2-13 Dump

Valve.

The platform option is configured

and the UGM detects an open

circuit at this output.

Power cycled.

Message

Fault

Code

Indicators

Other Actions Taken

Trigger for Fault

Latch Until