Electrical system – JLG 4013PS Service Manual User Manual

Page 208

background image

Electrical System

9-68

3508PS, 3509PS, 3512PS, 3513PS, 4008PS, 4009PS, 4012PS, 4013PS, 4017PS, 40.8, 40.9

DUMP VALVE –
SHORT TO
BATTERY

33214

1

Deactivate output J2-13 Dump

Valve.

Deactivate output J2-3 Right

Stabilizer Up Valve.

Deactivate output J2-5 Frame Level

Right Valve.

Deactivate output J2-7 Frame Level

Left Valve.

Deactivate output J2-8 Fork Tilt Up

Valve.

Deactivate output J2-9 Auxiliary

Function-A Valve.

Deactivate output J2-10 Left

Stabilizer Up Valve.

Deactivate output J2-11 Main Lift

Up Valve.

Deactivate output J2-15 Right

Stabilizer Down Valve.

Deactivate output J2-19 Fork Tilt

Down Valve.

Deactivate output J2-20 Auxiliary

Function-B Valve.

Deactivate output J2-21 Left

Stabilizer Down Valve.

Deactivate output J2-22 Main Lift

Down Valve.

Deactivate output J2-34 Main

Telescope In Valve.

Deactivate output J2-35 Main

Telescope Out Valve.

Deactivate output J1-3 Stabilizer

and Frame Level Speed Valve

(if applicable).

The platform option is configured

and the UGM detects a short to

battery at this output.

Power cycled.

DUMP VALVE –
SHORT TO
GROUND

33215

1

Deactivate output J2-13 Dump

Valve.

The platform option is configured

and the UGM detects a short to

ground at this output.

Power cycled.

AUXILIARY
FUNCTION SELECT
– OPEN CIRCUIT

33216

1

Deactivate output J2-1 Auxiliary

Function Select.

The CAT brand is configured for the

UGM, the PLATFORM STATION is

not active, and the UGM detects an

open circuit at this output.

Power cycled.

AUXILIARY
FUNCTION SELECT
– SHORT TO
BATTERY

33217

1

Deactivate output J2-1 Auxiliary

Function Select.

Deactivate output J2-9 Auxiliary

Function-A Valve.

Deactivate output J2-20 Auxiliary

Function-B Valve.

The CAT brand is configured for the

UGM and the UGM detects a short

to battery at this output.

Power cycled.

AUXILIARY
FUNCTION SELECT
– SHORT TO
GROUND

33218

1

Deactivate output J2-1 Auxiliary

Function Select.

Deactivate output J2-9 Auxiliary

Function-A Valve.

Deactivate output J2-20 Auxiliary

Function-B Valve.

The CAT brand is configured for the

UGM and the UGM detects a short

to ground at this output.

Power cycled.

Message

Fault

Code

Indicators

Other Actions Taken

Trigger for Fault

Latch Until