beautypg.com

Electrical system – JLG 4013PS Service Manual User Manual

Page 204

background image

Electrical System

9-64

3508PS, 3509PS, 3512PS, 3513PS, 4008PS, 4009PS, 4012PS, 4013PS, 4017PS, 40.8, 40.9

MAIN LIFT DOWN
VALVE –
OPEN CIRCUIT

33184

1

Deactivate output J2-22 Main Lift

Down Valve.

The UGM detects an open circuit at

this output or the UGM detects a

CURRENT FEEDBACK LOST

condition and sets an internal flag to

determine if this fault condition is

the reason for the fault.

Power cycled.

MAIN LIFT DOWN
VALVE –
SHORT TO
GROUND

33185

1

Deactivate output J2-22 Main Lift

Down Valve.

Decouple/disable current feedback
input J3-2 Lift Return (Disables Lift

Up and Down).

The UGM detects a short to ground

at this output or the UGM detects a

CURRENT FEEDBACK LOST

condition and sets an internal flag to

determine if this fault condition is

the reason for the fault.

Power cycled.

MAIN TELESCOPE
OUT VALVE – OPEN
CIRCUIT

33186

1

Deactivate output J2-35 Main

Telescope Out Valve.

The UGM detects an open circuit at

this output or the UGM detects a

CURRENT FEEDBACK LOST

condition and sets an internal flag to

determine if this fault condition is

the reason why.

Power cycled.

MAIN TELESCOPE
VALVES – SHORT
TO BATTERY

33187

1

Deactivate output J2-35 Main

Telescope Out Valve.

Deactivate output J2-34 Main

Telescope In Valve.

Decouple/disable current feedback

input J3-4 Telescope Return

(Disables Telescope Out and In).

The UGM detects a short to battery

at this output.

Power cycled.

MAIN TELESCOPE
OUT VALVE –
SHORT TO
GROUND

33188

1

Deactivate output J2-35 Main

Telescope Out Valve.

Decouple/disable current feedback

input J3-4 Telescope Return

(Disables Telescope Out and In).

The UGM detects a short to ground

at this output or the UGM detects a

CURRENT FEEDBACK LOST

condition and sets an internal flag to

determine if this fault condition is

the reason for the fault.

Power cycled.

MAIN TELESCOPE
IN VALVE – OPEN
CIRCUIT

33189

1

Deactivate output J2-34 Main

Telescope In Valve.

The UGM detects an open circuit at

this output or the UGM detects a

CURRENT FEEDBACK LOST

condition and sets an internal flag to

determine if this fault condition is

the reason for the fault.

Power cycled.

MAIN TELESCOPE
IN VALVE – SHORT
TO GROUND

33190

1

Deactivate output J2-34 Main

Telescope In Valve.

Decouple/disable current feedback

input J3-4 Telescope Return

(Disables Telescope Out and In).

The UGM detects a short to ground

at this output or the UGM detects a

CURRENT FEEDBACK LOST

condition and sets an internal flag to

determine if this fault condition is

the reason for the fault.

Power cycled.

FORK TILT UP
VALVE –
OPEN CIRCUIT

33191

1

Deactivate output J2-8 Fork Tilt Up

Valve.

The UGM detects an open circuit at

this output or the UGM detects a

CURRENT FEEDBACK LOST

condition and sets an internal flag to

determine if this fault condition is

the reason for the fault.

Power cycled.

Message

Fault

Code

Indicators

Other Actions Taken

Trigger for Fault

Latch Until