Brocade Communications Systems Brocade Backbone DCX 8510-4 User Manual
Page 71
![background image](/manuals/54677/71/background.png)
Brocade DCX 8510-4 Backbone Hardware Reference Manual
51
53-1002177-05
Determining the status of a core switch blade (CR16-4)
4
Determining the status of a core switch blade (CR16-4)
Complete the following steps to determine the status of a core switch blade (CR16-4).
1. Check the LED indicators on the core switch blade (see the following figure). The LED patterns
may temporarily change during POST and other diagnostic tests. For information about how to
interpret the LED patterns, refer to
2. Check the core switch blade status by entering slotShow and haShow.
identifies the core switch blade.
Status
No light (LED is off)
CP blade is either healthy
or does not have power.
Verify that the power LED is on.
Steady amber
CP blade is faulty or the
switch is still booting.
Ensure that the blade is firmly
seated and the switch has
completed booting. If LED remains
yellow, consult the Brocade DCX
8510-4 supplier.
Slow-flashing amber (on 2
seconds; then off 2 seconds)
CP blade is not seated
correctly or is faulty.
Pull the blade out and reseat it. If
the LED continues to flash, replace
the blade.
Fast-flashing amber (on 1/2
second; then off 1/2 second)
Environmental range
exceeded.
Check for out-of-bounds
environmental condition and
correct it.
Ethernet Link
Status
No light (LED is off)
Either an Ethernet link is
not detected, or it does not
have incoming power.
Ensure that the blade has power,
the Ethernet cable is firmly seated,
and the connected device is
functioning.
Flickering green/amber
Ethernet link is healthy
and traffic is flowing
through port.
No action required.
Ethernet Link
Speed
No light (LED is off)
Ethernet link speed is 10
Mb/s or CP blade does not
have incoming power.
Ensure that the CP has power.
NOTE: To force a persistent Ethernet
link speed, enter the ifModeSet
command.
Steady green
Ethernet link speed is
100/1000 Mb/s.
No action required.
USB Status
Lamp on
USB stick enabled.
No action required.
Lamp off
USB stick not present or
disabled.
No action required.
Active CP
Steady blue
Active CP blade.
No action required.
No light (LED is off)
Standby CP blade.
No action required.
TABLE 4
CP blade LED descriptions (Continued)
LED purpose
Color
Status
Recommended action