Input function assignments, A/c setup, Lowside assignment tables – AEM Infinity Supported Applications - Mitsubishi 2006 Evolution IX Engine User Manual
Page 6: Radiator fan control

6
© 2014 AEM Performance Electronics
Input Function Assignments
In the Wizard Input Function Assignments tab confirm the following setting:
AC Request Switch Setup = Digital 6
A/C Setup
Add a 1D Table for AC_Request_In. Populate the table as shown below.
LowSide Assignment Tables
In the Wizard Output Functions tab confirm the following settings:
LS5 Setup (Coolant Fan):
Frequency
= 20 Hz
LS5_Duty X-Axis
= Vehicle Speed (reassignable)
LS5_Duty Y-Axis
= Coolant Temp [C]
LS8 Setup (VVC1A):
Frequency
= 250 Hz
LS8_Duty X-Axis
= Engine Speed [RPM]
LS8_Duty Y-Axis
= VVC1A_Duty [%]
Radiator Fan Control
Populate the 2D LS5_Duty [%] table similar to the table below. A higher value in the LS5_Duty [%] table
will result in a faster fan speed (0% duty = max fan speed, 100% duty = fan off).