beautypg.com

AEM 30-1931 Universal Fuel Ignition Controller 8 Channel User Manual

Page 25

background image

Page 25

Uploading a Cal File:

This function is used to upload a calibration only. To upload a cal file to the FIC,

click on f

ile and select “Upload Cal Only”. Select the file to upload and click open.

Note: When using the “Upload Cal Only” function, the software will overwrite the
calibration in the FIC with the selected calibration.

Calibrating the FIC:

When an FIC is installed on a vehicle, it is necessary to calibrate the FIC before

any tuning is performed. With the FIC already connected, go to Setup>Calibration. The
calibration window will appear. See Figure 34.



The RPM calibration is performed by running the engine at the RPM shown in the RPM
box, as directed by the on-screen instructions. The RPM in the window can be changed
if desired. Click Auto in the rpm section and follow the on-screen instructions. The TPS
calibration is a two-point calibration, one at 0% throttle and one at 100% throttle. Click
Auto in the TPS section and follow the on-screen instructions to calibrate the TPS.
(Note: For drive by wire applications, the engine may need to be running in order to
open the throttle plate to 100%. Quickly blip the throttle to 100% and click the ok
button.) Always verify the TPS and RPM calibrations after uploading a file from a
different source. (Note: The TPS and RPM calibration settings are stored in the
calibration file.)












Figure 34. F/IC Calibration Window

This manual is related to the following products: