Gradall LOED 534A Service Manual User Manual
Page 58
5.
6.
7.
Use a stud driver or vise-grip pliers
and remove studs (42). (Fig. 79)
Grasp the drive gear shaft extension
(5) and lift it slightly with a
quick upward motion. This action
will dialogue the pressure plate (9)
(12, in SPM25) from the bore. Place
the thumb and forefinger of the
other hand in the slots of the
pressure plate. Release the drive
shaft and lift the pressure plate
from the body. (Fig. 80)
58
8.
9.
FIGURE 77
FIGURE 79
FIGURE 78
FIGURE 80
Keeping the flange (1) as straight
as possible, lift it off the shaft
and stud bolts. If the flange is
stuck, use a wooden mallet or
plastic hammer and tap around the
edge to loosen it. (Fig. 77)
Remove o-ring (33) from the flange.
Remove isolation plates (10), seal-
ing strips (17), end seperators (15),
center separators (16), back-up ring
(14), and o-ring (35). (No isolation
plates nor separators in SPM25.)
(Fig. 78)